| Index | Sell Offers | Buy Offers | Products | Companies | 
  •  CNEXP.NET > Sell Offers > Automobile > Offer: Sell geothermal power plant
  • Sell geothermal power plant


    Description:
    [China]

    We are main contractor of the 2x6mw geothermal power plant in Indonesia. Example of a geothermal main equipments specificationI. STEAM TURBINE - Admission pressure (Mpa abs) 0. 6 - Admission temperature (0C) 160 - Exhaust pressure (Mpa) 0. 0112 - Rotation speed (turbine and generator) (rpm) 3000 - Output at generator terminals (kW) 5773 - Capability (%) 100 II. DEMISTER - Steam flow (t/h) 48. 1 - Operating pressure (Mpa abs) 0. 75? 0. 8 - Operating temperature (0C) 165 - Design pressure (barg) 0. 8 II. MAIN STEAM STEEL PIPING Between Pertamina? S point of interface and turbine admission - Operating/design pressure (Mpa) 0. 65/1. 0 - Operating/design temperature (0C) 200 - Steam flow (t/h) 150 III. STEAM VALVES For all main steam isolation valves of large size - Design temperature (0C) 200 - Design pressure (Mpa) 1. 0 - Construction Flexible wedge gates Flanged ends By-pass line to permit line warming IV. CONDENSER Pressure at turbine exhaust (bar abs) 0. 0112 Exhaust steam enthalpy (kJ/kg) 141 V. NON CONDENSABLE GAS EXTRACTION Suction conditions Gases CO2 (kg/h) 71 Gases H2S (kg/h) 936 Air (kg/h) 29. 1 Discharge (bar abs) 0. 09 VI. MAIN COOLING WATER SYSTEM VII. PIPING 1. Hot Water Flow Pipework 2. Cold Water Return Pipework VIII. PUMP MOTORS Electric motor main characteristics (for each pump): - Voltage (kV): 0. 38 - Enclosure: IP 55 - Insulation class: F - Temperature rise class: B - Efficiency at full load: > 95% IX. COMPRESSOR - Type: - Number of Cylinder: - Number of stage: - Inter stage and final coolers - V belt drive X. OVERHEAD TRAVELING CRANE - Type: - Span (m): 13. 5 - Nominal loads (T): 20 - Traveling speedwith traveling limit switches: Fore-and-aft 20m/minRight-and-left 18m/min - Lifting hoist - Type: - Nominal load (T): 20 - Nominal lifting height (m): 14m above 0. 00 level ground - 2 lifting speedswith mechanical load limiter: Creep speed and normal speed7. 9m/min main lifting hoist 13m/min for 5T lifting hoist - Common hoists bearer trolley - Type: Bi-rail - Traversing speedwith traversing limit switches: Contractor to determine XI. GENERATOR - Active power (MW) 6 - Apparent power (MVA) 7. 5 - Power factor 0. 8 - Voltage (kV) 6. 3 - Rotation speed (R. P. M) 3000 R. P. M. - Frequency (HZ) 50 HZ - Number of phases 3 - Coupling of phases STAR - Class of insulation F - Standards IEC - Temperatures Stator (by embedded detectors) (0 C) 130 - (Max values); Rotor (by resistance variation) (0 C) 140 - Cooling water temperature (0 C) 33 - Short circuit ratio (about) 0. 52 XII. MAIN POWER TRANSFORMERS 1. Manufacturer? S name 2. Number 1 3. Rated voltage (a) High Voltage side (no load) kV 20 (b) Low Voltage (no load) kV 6. 3 4. Number of phase 3 5. Rated frequency Hz 50 6. Vector symbol Ynd11 7. Percent reactance drop at full load (750 C) (a) At nominal ratio tap % 7. 90 8. Percent resistance drop at full load (750 C) (a) At nominal ratio tap % 0. 10 9. Exciting current at nominal tap (a) At rated voltage Amp 4. 33 (b) At 105% of rated voltage Amp 4. 77 (c) At 110% of rated voltage Amp 5. 24 10. Cooling type ONAN XIII. STATION SERVICE TRANSFORMERS

    Company name:
    Location:
    Contact Person:
    Address:
    Zip/Postal:
    Telephone:
    Fax:
    China National Electric Wire&Cable Imp./Exp. Corp.
    China
    Mr. yang chunlin (Engineering)
    8 langjiayuan, Beijing, Beijing, China
    100026
    0086-10-84568952
    0086-10-84568952
    Related Products:  geothermal power plant, cooling tower, steam turbine, geothermal well, desulferation, generator, china, chinese turnkey contractor, power generation, breaker, mw, kw, china power contractor, electricity supplier, price, quotation, transportat

    Copyright © 2004-2006 Cnexp.Net Inc. All rights reserved.[Chinese Simplified] [SiteMap]